PVD on aluminium and steel: Sourcing nickel and PVD from the same supplier results in fewer deviations from the drawing

by | 23 November 2026 | Surface treatments, Physical Vapor Deposition

On the drawing, it rarely takes up more than a single line: base material aluminium, PVD finish in black chrome on a nickel base. In production, this involves two processes, and for many buyers it also means two suppliers, two orders, two shipments and two certificates that must all match up before the component can be fitted.

It is during the transition between the two that deviations occur. At Chem-Tec Plating in Uldum, the nickel undercoat and the PVD coating are carried out within the same company and under the same ISO 9001 quality management system, so that the specifications on the drawing are interpreted and implemented in a single location.

Can PVD be applied to aluminium?

Yes, but not directly. PVD can be applied directly to stainless steel and titanium; aluminium, carbon steel, copper and brass must first be given a nickel undercoat. The reason lies in the thickness. The PVD layer is typically 0.1 to 4.0 µm thick, and although it is hard and wear-resistant, it is so thin that it requires a solid substrate and corrosion protection, which these materials do not provide on their own. Electrolytically deposited nickel is typically applied at a thickness of 5 to 15 µm, and it is the combination of the two layers that gives the workpiece its colour, wear resistance and corrosion protection.

For aluminium and ordinary steel, therefore, the hybrid coating is a prerequisite for achieving a PVD surface at all.

The thin PVD layer also conforms to the surface beneath it. Whether the final finish is glossy or matt is therefore determined before the workpieces enter the vacuum chamber (a matt finish requires the workpieces to be glass-blown before they are coated). What happens in the nickel bath is reflected in the finished surface.

What is specification-based operation?

A deviation from specifications occurs when the finished coating deviates from what the drawings require, without any of the suppliers having breached their part of the agreement. It rarely becomes apparent in a single delivery. As a rule, it only becomes apparent after several months: a black chrome finish that is a shade different from the last batch, or a complaint about wear and tear that no one can trace back to a specific stage of the process.

Once the task has been divided up, there are several points at which production can begin. The drawing is read twice, by two companies, each looking for their own specific part; the requirements for the whole (finish, appearance, where on the workpiece measurements are taken) have no natural owner. The tolerances are superimposed on one another, so that a nickel layer at the lower end of the tolerance range and a PVD layer at the lower end of the tolerance range may each be approved individually and yet produce a result different from the test samples you approved. If the nickel supplier adjusts its pre-treatment within its own tolerance, it has no reason to pass this on, and the PVD supplier only discovers it when the workpieces look different after leaving the chamber. If they notice it at all. And when the certificates arrive, the coating thicknesses have been measured using different equipment and perhaps at different points on the workpiece, so they cannot immediately be combined to give a single picture of the coating.

The unit price shows only part of the bill

It may well be that two specialist suppliers together offer a lower price per item. However, the operational costs are simply passed on elsewhere: in the form of two supplier approvals and two audits, in engineering hours spent identifying where things went wrong, and, most costly of all, in discarded batches and complaints from your own customers. None of these items appear on the invoice for surface treatment. That is why they are rarely taken into account when comparing two quotes.

We have previously written about, who is responsible when a hybrid surface fails, and whether, where the delivery time is lost between two suppliers. Operating to specifications rarely results in a major issue. It adds a small cost to each production run.

At Chem-Tec, the specification accompanies the workpiece through both stages

Every order leaves Uldum with a certificate showing the order’s master data, the average layer thickness, the adhesion test results and the measuring equipment used. The measurements are carried out in our own control room using XRF equipment, micrometre screws and microscopes, and production data is stored in a single ERP system. A batch can therefore be traced back through both the nickel plating bath and the vacuum chamber, without anyone having to request data from another company.

The Quality, Production, Development and Sales teams meet every morning to go through current issues. If an operator notices anything about the workpieces that could affect the result, we will contact you via the Quality or Sales departments before proceeding. For procurement, this means just one supplier to approve and audit, one order and one point of contact. Nor do the items need to be packed and sent between the two stages.

Write the full layout on the drawing

Regardless of who is covering the topic, the result will be more consistent if the diagram illustrates the entire structure rather than just the individual layers. It is worth including these five points:

  1. The base material; in the case of aluminium, the alloy as well.
  2. The PVD colour, and whether the finish should be glossy or matt.
  3. The functional requirements, such as wear resistance, corrosion protection or electrical conductivity.
  4. Requirements regarding the thickness of both layers, and where on the workpiece the measurements are to be taken.
  5. Which surfaces are visible or functional, and which are not.

If you’re unsure about the structure, it’s cheaper to ask, before the drawing is locked, rather than correcting it afterwards.

If you have an aluminium or steel component that is currently being treated with nickel and PVD by two suppliers, or which is to receive a PVD finish for the first time, please send the drawing and specification to info@chemtec.dk. We’ll first check whether the workpiece is suitable for both processes. The PVD chamber accommodates workpieces up to 1,000 mm in length and Ø300 mm (black chrome up to 800 mm), whilst the nickel lines have their own dimensions. We will then get back to you with a proposal for the design and how a comprehensive solution would alter your specifications. You can also call us on +45 75 67 92 92.

Contact us and learn how we can help you

We help you find the right solutions within surface treatment. Contact us to find out more about how we can optimize your process and deliver a result that matches your requirements.

Write an email to info@chemtec.dk or call us at +45 75 67 92 92.